Relay conditioners: 
EJH  product range includes converter modules with relay outputs for applications such as pulse inputs or analog control, alarm management , remote controls, set-points, thresholds and digital outputs control, timing and switching status.
 
EZ-TIMER-D:   Electronic timer with microprocessor, 2 independent time
EZ112A:   On/Off sensors digital amplifier, single channel
EZ112D:   On/Off sensors amplifier, double channel
EZ113D:   DC current / voltage, double alarm trip module
EZ113S:   DC current / voltage single alarm trip module
EZ113T:   DC current / voltage triple alarm trip module
EZ113-1:   Double threshold with universal analog input

EZ112A

On/Off sensors digital amplifier, single channel


On/Off sensors digital amplifier, single channel  
EZ112 is an amplifier for ON/OFF sensors and provides a relay output. It’s available as single channel (Z112A) or independent double channel (Z112D). The single channel dispose also of pulse division system (from 1 to 256). Also the lenght of pulse output is configurable from 100ms to 500ms. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ112A
Description:   On/Off sensors digital amplifier, single channel
Power supply:   19..40 (option 9..30) Vdc; 19..28 Vac 50-60 Hz
Isolation:   1.500 Vac
Input:   free contact, npn/pnp 2-3 wire, 24 Vdc, namur, photoelectric, Hall sensor, variable reluctance
Output:   Nr 1 relay SPDT (5 A, 250 Vac)
Pulse divider:   1..256 configurable via Dip-Switch

EZ112D

On/Off sensors amplifier, double channel


On/Off sensors amplifier, double channel  
EZ112 is an amplifier for ON/OFF sensors and provides a relay output. It’s available as single channel (EZ112A) or independent double channel (EZ112D). The single channel dispose also of pulse division system (from 1 to 256). Also the lenght of pulse output is configurable from 100 ms to 500 ms. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ112D
Description:   On/Off sensors amplifier, double channel
Power supply:   19..40 (opt. 9..30) Vdc; 19..28 Vac 50-60 Hz
Isolation:   1.500 Vac
Input:   2-CH; free contact, npn/pnp 2-3 wire, 24 Vdc, namur, photoelectric, Hall sensor, variable reluctance
Output:   SPST relay (5 A, 250 Vac)

EZ113-1

Double threshold with universal analog input


Double threshold with universal analog input  
EZ113-1 is double alarm threshold with universal analog input and two relays common SPST 3 A@ 250Vac, 3 A@ 30Vdc. The input can be configured as voltage, current, potentiometer, thermocouples or thermoresistances. The current input can be set in passive or active mode in order to provide power to the sensor. EZ113-1 can be programmed by PC through a microUSB front connector where it is possible to configure the two alarm output, the input filter, the rejection and the burn-out. The isolation between input and power supply is 1500 Vac and 3000 Vac towards the outputs. On front panel status indicators are available for power on, out of range/burn out error and the alarm for each output.

Order code :   EZ113-1
Description:   Double threshold with universal analog input
Power Supply:   10..40 Vdc, 19..28 Vac
Power transducer:   Yes (current input)
Isolation:   1.500 Vac between input // power supply, 3.000 Vac towards output
Input:   Nr 1 channel mA, V, Ohm, RTD, TC
Output:   Nr 2 threshold SPST relay, 3 A, 250 Vac
Settings:   Via software and mini USB port (EASY SETUP)
Operating Temperature:   -10..+65°C

EZ113D

DC current / voltage, double alarm trip module


DC current / voltage, double alarm trip module  
EZ113D is a 2-CH relay output converter that accepts a programmable analog input for current and voltage signals. It's provided by stable power supply for transducers in 2-wire short circuit protection. Z113D allows to set the values of the set-point alarm, the delay time and hysteresis. The module allows to select the alarm type (minimum or maximum) for each set-point and relay status.

Order code :   EZ113D
Description:   DC current / voltage, double alarm trip module
Power supply:   19..40 (opt. 9..30) Vdc; 19..28 Vac 50-60 Hz
Isolation:   1.500 Vac
Input:   Current 0..20, 4..20; voltage 0..5, 1..5, 0..10, 2..10 Vdc
Output:   Nr 2 SPST relè (5 A, 250 Vac)
Linerarity:   0,05%
Settings:   alarm, cut-in delay, hysteresis set-points

EZ113S

DC current / voltage single alarm trip module


DC current / voltage single alarm trip module  
EZ113S is a 1-CH relay output converter that accepts a programmable analog input for current and voltage signals. It's provided by stable power supply for transducers in 2-wire short circuit protection. Z113S allows to set the values of the set-point alarm, the delay time and hysteresis. The module allows to select the alarm type (minimum or maximum) for each set-point and relay status.

Order code :   EZ113S
Description:   DC current / voltage single alarm trip module
Power supply:   19..40 (optz. 9..30) Vdc; 19..28 Vac 50-60 Hz
Isolation:   1.500 Vac
Input:   Current 0..20, 4..20, voltage 0..5, 1..5, 0..10, 2..10 Vdc
Output:   1 SPDT relay (5 A, 250 Vac)
Linearity:   0,05%
Settings:   Alarm, cut-in delay, hysteresis set-poins

EZ113T

DC current / voltage triple alarm trip module


DC  current / voltage triple alarm trip module  
EZ113T is a 3-CH relay output converter that accepts a programmable analog input for current and voltage signals. It's provided by stable power supply for transducers in 2-wire short circuit protection. EZ113T allows to set the values of the set-point alarm, the delay time and hysteresis. The module allows to select the alarm type (minimum or maximum) for each set-point and relay status.

Order code :   EZ113T
Description:   DC current / voltage triple alarm trip module
Power supply:   19..40 (opt. 9..30) Vdc; 19..28 Vac 50-60 Hz
Isolation:   1.500 Vac
Input:   Current 0..20, 4..20; voltage 0..5, 1..5, 0..10, 2..10 Vdc
Output:   Nr 3 SPST reed relè (5 A, 250 Vac)
Linearity:   0,05%
Settings:   alarm, cut-in delay, hysteresis set-points

ETAP Users - Listed by Industry Electrical Engineering Consulting Firms ETAP

工程咨询

ETAP Users - Listed by Industry Data Centers ETAP

数据中心

ETAP Users - Listed by Industry Oil & Gas ETAP

采油平台

ETAP Users - Listed by Industry Generation Plants ETAP

发电厂

ETAP Users - Listed by Industry Nuclear Generation ETAP

核电厂

ETAP Users - Listed by Industry Transmission & Distribution ETAP

输配电

ETAP Users - Listed by Industry Government & Military Facilities ETAP

政府及军事设施

ETAP Users - Listed by Industry Metals & Mining ETAP

冶金矿业

ETAP Users - Listed by Industry Manufacturing ETAP

制造业

ETAP Users - Listed by Industry Renewable Energy ETAP

可再生能源

ETAP Users - Listed by Industry Transportation ETAP

铁路运输系统

ETAP Users - Listed by Industry Education - Colleges & Universities ETAP

教育系统