收藏 设为首页 搜索

HDR 200 Humidity and Dew Point Transmitters    订购编号:

点击这里发送询价

请详细填写一下内容,包括产品原产国、品牌完整名称以及您所能得到的所有信息,这将有助于我们准确迅速的报价。非常感谢!

品牌厂商(Manutacturer)*

公司名称*

产品名称(Product Name)*

联系人*

产品型号(Product Type)*

联系地址*

产品序列号(ID-Nr;Artikel-Nr)

联系电话*

产品描述(Voltage,Amp,Kw,Rpm)

传真*

需求数量(Quantity demanded)

联系邮箱*

附加信息,更具体要求

HDR 200 Series



Humidity and Dew Point Transmitters

HDR200 series is the perfect unit for applications for compressed air, dryers and environmental chambers

User selectable switches for C or F, and RH or dew point

    Dew point: -60C to 40C (factory default)
    RH 0-95%RH (non-condensing)
    Unit Displays Dew point and temperature or RH and temperature
    ½”NPT Fitting included
    Calibration done at -60C
    Pressure Rating: 750PSI
    Material: 304 SS
    Operating Temperature: 0 to 200C
    Mesh Filter Top (SS)-removable-washable
    Dew point accuracy:
        +/- 1.0C from
        +40c to -20C+/- 3.0C <-20C
    RH Accuracy: +/-1% from 15C to 40C (0 to 90%);+/- 2% >90% (non-condensing) <15C, >40C temperature, RH accuracy is +/-2%
    NIST Calibration Certificate included with each unit
    2 Line LCD
    Resolution: 0.1
    One 4-20mA loop powered output
    24VDC (typ)- 12-28VDC
    Dimensions of Probe: Length:
        4” (10.16cm)
        O. D.: 0.5” (1.27cm)
    Enclosure Dimensions: 3.5”L X 2.5” W (Display dimension)
    Enclosure Mounting Centers: 3.1” (Display mounting centers)
    Cable length is 1M (additional lengths are available, consult factory)

Humidity and Dew Point Transmitters

HDR200 series is the perfect unit for applications for compressed air, dryers and environmental chambers

User selectable switches for C or F, and RH or dew point

  • Dew point: -60C to 40C (factory default)
  • RH 0-95%RH (non-condensing)
  • Unit Displays Dew point and temperature or RH and temperature
  • ½”NPT Fitting included
  • Calibration done at -60C
  • Pressure Rating: 750PSI
  • Material: 304 SS
  • Operating Temperature: 0 to 200C
  • Mesh Filter Top (SS)-removable-washable
  • Dew point accuracy:
    • +/- 1.0C from
    • +40c to -20C+/- 3.0C <-20C
  • RH Accuracy: +/-1% from 15C to 40C (0 to 90%);+/- 2% >90% (non-condensing) <15C, >40C temperature, RH accuracy is +/-2%
  • NIST Calibration Certificate included with each unit
  • 2 Line LCD
  • Resolution: 0.1
  • One 4-20mA loop powered output
  • 24VDC (typ)- 12-28VDC
  • Dimensions of Probe: Length:
    • 4” (10.16cm)
    • O. D.: 0.5” (1.27cm)
  • Enclosure Dimensions: 3.5”L X 2.5” W (Display dimension)
  • Enclosure Mounting Centers: 3.1” (Display mounting centers)
  • Cable length is 1M (additional lengths are available, consult factory)
ETAP Users - Listed by Industry Electrical Engineering Consulting Firms ETAP

工程咨询

ETAP Users - Listed by Industry Data Centers ETAP

数据中心

ETAP Users - Listed by Industry Oil & Gas ETAP

采油平台

ETAP Users - Listed by Industry Generation Plants ETAP

发电厂

ETAP Users - Listed by Industry Nuclear Generation ETAP

核电厂

ETAP Users - Listed by Industry Transmission & Distribution ETAP

输配电

ETAP Users - Listed by Industry Government & Military Facilities ETAP

政府及军事设施

ETAP Users - Listed by Industry Metals & Mining ETAP

冶金矿业

ETAP Users - Listed by Industry Manufacturing ETAP

制造业

ETAP Users - Listed by Industry Renewable Energy ETAP

可再生能源

ETAP Users - Listed by Industry Transportation ETAP

铁路运输系统

ETAP Users - Listed by Industry Education - Colleges & Universities ETAP

教育系统